CH-100, Heating/Cooling Dry Block with CH-1 block for 20 x 0.5 ml + 12 x 1.5 ml microtubes
CH-100 is the result of combining two popular Biosan instruments:
The combined construction of aluminium block and Peltier element module cooled with the forced ventilation radiator provides fast changing of the cooling and heating modes.
CH-100 is a very effective instrument of sample preparation during enzyme reactions, hybridization reactions, DNA analysis.
Microprocessor controlled time and temperature. Simultaneous indication of set and actual temperature and time.
Blocks (built in) capacity:
1) with CH-1 block for 20 x 0.5 ml + 12 x 1.5 ml microtubes;
Temperature setting range | –10°C ... +100°C |
Temperature control range | 30°C below ambient ...+100°C |
Temperature setting resolution | 0.1°C |
Temperature stability | ±0.1°C |
Temperature uniformity at +37°C | ±0.1°C |
Temperature calibration coefficient range | 0.936...1.063 (± 0.063) |
Digital time setting | 1 min – 96 hrs / non–stop (increment 1 min) |
Display | LCD, 2 х 16 signs |
Overall dimensions (W×D×H) | 240х260х165 mm |
Weight | 3.2 kg |
Input current/power consumption | 12 V, 4.4 A / 55 W |
External power supply | Input AC 100–240 V 50/60 Hz, Output DC 12 V |
![]() |
||||
You are viewing:
CH-100, Heating/Cooling Dry Block
|
||||
Price
|
Price
€1,250.00
|
Price
€761.80
|
Price
€761.80
|
Price
€1,676.20
|
Reference
|
Reference
BS-010410-BAI
|
Reference
BS-010412-AAA
|
Reference
BS-010401-QAA
|
Reference
BS-010418-AAA
|
Short description
|
Short description
CH-100, Heating/Cooling Dry Block with CH-1 block for 20 x 0.5 ml + 12 x 1.5 ml microtubes
|
Short description
Bio TDB-100 is a compact easy–to–use dry block thermostat designed for long incubation processes at various temperatures, for 1,5 - 0,5 e 0,2ml microtubes. With integrated Block.
|
Short description
TDB-120, Dry block thermostat with lid for 21 × 0.5 ml + 32 × 1.5 ml microtubes
|
Short description
Combined cold / heating thermostat with two individually adjustable blocks for microtubes, tubes and containers.Blocks not included
|
Manufacturer
|
Manufacturer
Biosan
|
Manufacturer
Biosan
|
Manufacturer
Biosan
|
Manufacturer
Biosan
|
TBH - TYPE
|
TBH - TYPE
heater with cooling
|
TBH - TYPE
heater
|
TBH - TYPE
heater
|
TBH - TYPE
heater with cooling
|
TBH - No BLOCKS
|
TBH - No BLOCKS
1
|
TBH - No BLOCKS
1
|
TBH - No BLOCKS
1
|
TBH - No BLOCKS
2 independent
|
TBH - WITH COOLING
|
TBH - WITH COOLING
you
|
TBH - WITH COOLING
no
|
TBH - WITH COOLING
no
|
TBH - WITH COOLING
you
|
TBH - TEMPERATURE MAXIMUM
|
TBH - TEMPERATURE MAXIMUM
+100°C
|
TBH - TEMPERATURE MAXIMUM
+100°C
|
TBH - TEMPERATURE MAXIMUM
+120°C
|
TBH - TEMPERATURE MAXIMUM
+150°C / +20°C
|
TBH - MINIMUM TEMPERATURE SET
|
TBH - MINIMUM TEMPERATURE SET
-10°C
|
TBH - MINIMUM TEMPERATURE SET
+25°C
|
TBH - MINIMUM TEMPERATURE SET
+25°C
|
TBH - MINIMUM TEMPERATURE SET
+25°C / -3°C
|
TBH - THE MINIMUM TEMPERATURE REACHED
|
TBH - THE MINIMUM TEMPERATURE REACHED
30° below ambient (10°C)
|
TBH - THE MINIMUM TEMPERATURE REACHED
+25°C above ambient
|
TBH - THE MINIMUM TEMPERATURE REACHED
+5°C above ambient
|
TBH - THE MINIMUM TEMPERATURE REACHED
5 °C / 25°C sotto temp. ambiente
|
TBH - POWER HEATING
|
TBH - POWER HEATING
200W
|
TBH - POWER HEATING
200W
|
TBH - POWER HEATING
500W
|
|
TBH - RESOLUTION SETTING
|
TBH - RESOLUTION SETTING
0,1°C
|
TBH - RESOLUTION SETTING
0,1°C
|
TBH - RESOLUTION SETTING
0,1°C
|
|
TBH - PRECISION
|
TBH - PRECISION
0,1°C
|
TBH - PRECISION
0,1°C
|
TBH - PRECISION
0,1°C
|
TBH - PRECISION
0,1°C
|
TBH - UNIFORMITY
|
TBH - UNIFORMITY
0,1°C
|
TBH - UNIFORMITY
0,1°C
|
TBH - UNIFORMITY
0,1°C
|
TBH - UNIFORMITY
0,1°C
|
TBH - DISPLAY
|
TBH - DISPLAY
LCD
|
TBH - DISPLAY
LCD
|
TBH - DISPLAY
LCD
|
TBH - DISPLAY
LCD
|
TBH - TIMER
|
TBH - TIMER
da 1m a 96h
|
TBH - TIMER
da 1m a 96h
|
TBH - TIMER
da 1m a 96h
|
TBH - TIMER
da 1m a 99h
|
TBH - PROGRAMS
|
TBH - PROGRAMS
not provided
|
TBH - PROGRAMS
not provided
|
TBH - PROGRAMS
not provided
|
TBH - PROGRAMS
16 heating / cooling
|
TBH - AUTONOMY
|
TBH - AUTONOMY
nd
|
TBH - AUTONOMY
nd
|
TBH - AUTONOMY
nd
|
|
TBH - COMPLIANCE
|
TBH - COMPLIANCE
CE
|
TBH - COMPLIANCE
CE
|
TBH - COMPLIANCE
CE
|
TBH - COMPLIANCE
CE
|
TBH - FREE
|
TBH - FREE
no
|
TBH - FREE
no
|
TBH - FREE
no
|
TBH - FREE
no
|
TBH - INDEPENDENT BLOCK
|
TBH - INDEPENDENT BLOCK
no
|
TBH - INDEPENDENT BLOCK
no
|
TBH - INDEPENDENT BLOCK
you
|
|
TBH - ACCESSORIES INCLUDED
|
TBH - ACCESSORIES INCLUDED
integrated lock and cover
|
TBH - ACCESSORIES INCLUDED
integrated lock
|
TBH - ACCESSORIES INCLUDED
integrated lock and cover
|
TBH - ACCESSORIES INCLUDED
lids
|
TBH - OPTIONAL ACCESSORIES
|
TBH - OPTIONAL ACCESSORIES
blocks various sizes
|
|||
TBH - POWER
|
TBH - POWER
230 V 50/60 Hz
|
TBH - POWER
230 V 50/60 Hz
|
TBH - POWER
230 V 50/60 Hz
|
|
TBH - WARRANTY
|
TBH - WARRANTY
12 months on manufacturing defects
|
TBH - WARRANTY
12 months on manufacturing defects
|
TBH - WARRANTY
12 months on manufacturing defects
|
TBH - WARRANTY
12 months on manufacturing defects
|
TBH - SIZE
|
TBH - SIZE
295х285х220 mm
|
|||
TBH - WEIGHT
|
TBH - WEIGHT
5.6kg
|
|||
TBH - FEATURES
|
TBH - FEATURES
two blocks, one heating from +25 to +150°C , and the other for cooling and -3°C to +20°C
|
|||
TBH - TO BE USED WITH
|
TBH - TO BE USED WITH
microtubes 0.5 ml
|
TBH - TO BE USED WITH
microtubes 0.2 ml
|
TBH - TO BE USED WITH
microtubes 0.2 ml
|
TBH - TO BE USED WITH
microtubes 1.5 ml
|
TBH - IDEAL FOR
|
TBH - IDEAL FOR
PCR analysis
|
TBH - IDEAL FOR
cell biology
|
TBH - IDEAL FOR
cell biology
|
Quotazione per quantità o per PA/MePA: Clicca qui